Product introduction:
Vaping resistance test is mainly used to measure the vaping resistance performance of vaping dry, which is suitable for quality control and inspection of
vaping production. When inhaling air with a fixed flow rate of 175ML/S is simulated on the e-cigarette, a certain vacuum pressure will be generated at the
suction end of the e-cigarette. This pressure is the suction resistance, referred to as the suction resistance. By measuring this pressure, the suction resistance
can be measured.
Product parameter:
unit | Pa (Pa), twg (mm water column) |
Gas flow rate | 5-33ml/s can be set (standard requirement is 175ml/s) |
resolution | 0.1 |
error | <1% |
Test time | Average 5 seconds |
Test sample straight warp | 7.7mm(Test clamps of other calibers can be customized) |
Insertion depth | 9mm |
Protective device | Leakage, short circuit, overload, pressure over capacity, air flow over capacity, etc |
Other functions | Upper and lower limits can be set, automatically judge whether the sample is qualified |
volume | 580×380x420mm(WxDxH) |
weight | 28 kg |
Power supply | AC220V, 50Hz, about 330w |