Static ozone aging test chamber

Static ozone aging test chamber

The ozone aging test chamber simulates and strengthens the ozone conditions in the atmosphere, studies the effect of ozone on rubber, and quickly identifies and evaluates the anti-ozone aging performance of rubber and the method of anti-ozonant protection. It is suitable for the aging test of non-metallic materials and organic materials (coatings, rubber, plastics, paints, pigments, etc.) under ozone conditions.

Description

Features of Dynamic ozone aging test chamber

1. The content of ozone in the atmosphere is very small, but it is the main factor for rubber cracking. This product simulates and strengthens the ozone conditions in the atmosphere, studies the effect of ozone on rubber, and quickly identifies and evaluates the anti-ozone aging performance and anti-ozone properties of rubber. Method for the protective efficacy of the agent. Reference standards: GB/T7762-2003 vulcanized rubber or thermoplastic rubber ozone crack resistance static tensile test method, GB/T2951.21-2008 General test method for cable insulation and sheathing materials, GB/T 11206- 2009 Rubber aging test surface cracking method, and test methods specified in other relevant standards.


2. Principle and method - The test method can be divided into "static" and "dynamic" according to the test method and standard. Static means that the sample is placed in the test box for testing after being stretched, and dynamic means that the sample is placed in the test box. On the fixture, the test is performed while stretching, and the tensile fluctuation is about 5%-45% of the tested sample itself.



Parameters of Dynamic ozone aging test chamber


ModelHJ-100HJ-225HJ-500HJ-800HJ-1000
Studio size DxWxH(mm)450x450x450500x600x750700x800x9001000x800x10001000x1000x1000
Dimensions DxWxH(mm)1060x880x16701110x1030x18701130x1410x20201610x1430x21201610x1430x2120
Total power3KW4.2KW4.7KW5.7KW6KW
temperature range5℃--70℃(Test conditions:40℃)
Ozone concentration50 ~ 500pplm 100 ~ 500ppm
Temperature fluctuation±0.5t
Sample rack speed360 degree rotating sample holder (rotating speed 1 revolution per minute)
Ozone control accuracy±10%
Moderate range50%~95%R.H



Related Product

Chat with us