Features of UV aging testing machine
The UV aging test chamber uses a fluorescent UV lamp as the light source. By simulating the UV radiation and condensation in natural sunlight, the accelerated weather resistance test of the material is carried out to obtain the weather resistance result of the material. It can simulate the environmental conditions of ultraviolet, rain, high temperature, high humidity, condensation, darkness and other environmental conditions in the natural climate. By reproducing these conditions, it can be combined into a cycle and let it automatically execute the number of cycles.
Test standards for UV aging testing machine
ASTM G 153, ASTM G 154, ASTM D 4329, ASTM D 4799, ASTM D 4587, SAE, J2020, ISO 4892 All current UV aging test standards
Parameters of UV aging testing machine
Studio size | W1130mm×H400mm×D500mm |
Dimensions | W1300mm×H1400mm×D700mm |
Distance from lamp to product | Adjustable (up to 450mm) |
The distance between the specimen and the nearest parallel surface of the lamp surface | About 100mm |
Wavelength range | UV-A wavelength range is 315~400nm/UV-B wavelength range is 290~315nm |
Radiation intensity | 1.2W/m2/340nm |
Temperature resolution | 0.1℃ |
light temperature range | 50℃~70℃/Temperature tolerance is ±3℃ |
Condensing temperature range | 40℃~60℃/Temperature tolerance is ±3℃ |
Blackboard Thermometer Measurement Range | 30~80℃/Tolerance is ±1℃ |
Temperature control method | PID self-tuning temperature control mode |
Humidity range | About 45%~70%R.H (light state)/98% or more (condensation state) |
Sink Requirements | The water depth is not more than 25mm, and there is an automatic water supply controller |
Standard specimen size | 1000×400mm |
Recommended instrument use environment | 5~35℃, 40%~85%R·H, 300mm from the wall |